Radwin Manager 11.0 78 ((new)) Jun 2026
For critical infrastructure, version 11.0.78 introduces a dedicated dashboard for hot-standby management. It visually displays the state of the Ethernet bridge failover. If your primary fiber path fails, the secondary Radwin link’s latency is shown in green (<1ms switchover).
and planning tools to ensure optimal radio placement and alignment during deployment. Monitoring and Maintenance radwin manager 11.0 78
A network operator upgraded Radwin Manager to 11.0 build 78 to support new Radwin 5000 HPMP units. However, after the upgrade, older Radwin 2000 links showed intermittent “Agent unreachable” errors. The issue traced back to a change in the default SNMP timeout in build 78 — aggressive polling flooded older radios. The fix? Downgrading to build 71 or manually adjusting polling intervals. Build 78 was later replaced by 11.0.81, which reverted the timeout logic. For critical infrastructure, version 11