For particles > 0.5 µm, inertial impaction dominates:
If you are developing an in-house tool for repeated use, consider adding: venturi scrubber design calculation xls
You can also build your own using the equations above in about 30 minutes. For particles > 0
At=Qgvtcap A sub t equals the fraction with numerator cap Q sub g and denominator v sub t end-fraction Qgcap Q sub g = Volumetric gas flow rate ( = Throat velocity ( B. Liquid-to-Gas Ratio ( The amount of liquid per unit gas. ) from industrial gas streams, often achieving efficiencies
) from industrial gas streams, often achieving efficiencies exceeding 99%. Proper design is critical, as it requires balancing high-speed particulate collection with energy consumption. Developing a (Excel spreadsheet) is the standard approach for engineers to iterate through throat velocity, liquid-to-gas ( ) ratios, and pressure drop estimations.
A well-structured typically contains 6 worksheets (tabs):
Usually ranges from 0.5 to 2.5 gallons per 1,000 cubic feet. It is a primary driver of efficiency. Throat Velocity (