A: No. The resolution of the KK-613D is 0.01mm, but the mechanical accuracy is ±0.02mm. This is normal for a caliper in this price range. It quantizes the reading.
| Problem | Probable Cause | Solution | |---------|---------------|----------| | No display | Dead battery | Replace LR44 battery | | Flashing or random numbers | Low battery, moisture, or dirty scale | Clean scale, dry unit, replace battery | | Display stuck on one number | Electronic glitch | Remove battery for 30 seconds, reinstall | | Does not zero | Jaws not fully closed or dirt | Clean jaws and beam, retry | | Inconsistent readings | Loose locking screw or worn battery | Tighten screw, replace battery | | Accuracy off (e.g., 10mm reads 9.98mm) | Mis-zero or scale contamination | Clean scale, re-zero at full close | kenko kk-613d manual
Never use ABS mode unless you are performing comparative measurements against a gauge block. For 99% of users, ignore the ABS button entirely. It quantizes the reading
A: Zero at a reference dimension, then measure – the reading is the difference. A: Zero at a reference dimension, then measure
Do you need help a specific button that isn't responding, or