Xk3190-c8 Manual — Trusted

| Param | Function | Deep Note | |-------|----------|------------| | P01 | Division size (d) | Legal trade requires d = e (verification division). Can set 1,2,5,10,20,50 | | P02 | Decimal point | 0,1,2,3. Affects display and print | | P03 | Zero tracking range | 0.0 to 4.5 d/s – set higher for windy environments, lower for precision lab | | P10 | Digital filter strength | 0 (no filter) to 4 (heavy). Use 2 for truck scales, 4 for slow filling | | P27 | Motion detection sensitivity | Lower value = less sensitive (good for vibration) | | P44 | RS232 continuous output mode | Format: ST,GS,US (stable/unstable). Set to “ST” only for legal trade | | P65 | Sleep timer (auto-off) | 0=disabled. Set to 30 min for battery-powered mobile scales |

Used for navigating menus and modifying parameter values. xk3190-c8 manual

24-bit Σ-Δ conversion with a speed of 80 times/sec. | Param | Function | Deep Note |

The XK3190-C8 will then output via the relay board (optional) to start/stop feeders automatically. Use 2 for truck scales, 4 for slow